With IBM OS Release 6.0 support has been added for the IBM 5317, and
IBM 5327 Japanese printers.
To configure the 5227/5317/5327 printers for operation, the following
needs to be done:
1. In the spooler_configuration.tin file that resides in
(master_disk)>system>configuration, set the device_protocol
field as follows.
ibm5227 : device_protocol 4
ibm5327 : device_protocol 5
ibm5317 : device_protocol 6
2. If this is a change to the spooler_configuration.tin file, create
a new spooler_configuration.table file and copy it into the
(master_disk)>system directory.
(For information on creating files, refer to the System Admini-
strator's Guide.)
3. Define the ibm5227.ttp using the define_terminal_type command.
4. Use the update_channel_info command to set the terminal_type for
the port to ibm5227, using the -reset option.
NOTE: The ibm5227.ttp terminal_type can be used for all three
printers (5227/5317/5327).
5. Rename aetab.table.init in (master_disk)>system>configuration
to aetab.table and copy it into (master_disk)>system directory.
6. Login the spooler.